Wall Girts and Beam Structures in Steel Buildings

Wall Girts and Beam Structures in Steel Buildings

Wall girts and beams are the members that turn a bare steel frame into a finished building. Understanding their roles helps buyers check a quotation and spot missing items before construction begins.

What Are Wall Girts

A girt (also called a wall beam or sheeting rail) is a horizontal member fixed between columns to support wall cladding. It transfers wind pressure and cladding weight back into the frame.

Girts vs Purlins

Feature Wall Girt Roof Purlin
Location Vertical wall plane Roof slope
Main load Wind pressure and cladding Roof dead, snow and uplift
Typical section C or Z cold-formed C or Z cold-formed
Spacing Matched to sheet length, often 1.0–1.5 m Matched to sheet span
Bracing Diagonal bracing in wall plane Sag rods along roof

Beam Structures in a Steel Building

  • Rafter: the main roof beam spanning between columns.
  • Tie beam: horizontal member tying rafters and resisting thrust.
  • Crane beam: heavy beam carrying an overhead crane runway.
  • Floor beam: beam supporting mezzanine or upper floor loads.
  • Edge beam: perimeter beam at openings and canopy edges.

Alignment and Bracing

Girts must align with column flanges and be braced in the wall plane. A wall without diagonal bracing can rack under wind load even when the roof is fully braced, so specify wall bracing on the drawing.

See crane workshop design or request a wall framing layout.