Steel Structure

Surface Preparation and Coating for Steel Structures

Surface Preparation and Coating for Steel Structures

Coating performance depends far more on surface preparation than on paint brand. A well-prepared surface lets the coating bond and resist corrosion for years; a poorly prepared one fails early regardless of the topcoat.

Why Surface Preparation Comes First

Mill scale, rust, oil and salt residues block adhesion. Abrasive blasting removes them and creates a profile the primer can grip.

Surface Grade Description Typical Use
Sa 2.5 Near-white blast, only slight shadows Standard for structural steel
Sa 3 White metal blast Severe corrosive environments
Sa 2 Thorough blast, light residues Moderate service conditions
St 2/3 Hand or power tool cleaning Site touch-up only

Coating System Layers

Layer Function Typical DFT
Primer Adhesion and early corrosion protection 40–80 µm
Intermediate Barrier and build thickness 60–120 µm
Topcoat Weather, UV and colour 40–60 µm

Quality Control

  • Surface cleanliness: verify grade and salt level before priming.
  • Dry film thickness (DFT): measure each coat against the specification.
  • Adhesion: pull-off or cross-cut test on sample areas.
  • Holiday detection: check for pinholes and missed edges.

Site Repair

Welding and handling damage coating during erection. Site repair should use a compatible product and match the specified DFT, otherwise corrosion starts at the repair.

Compare options in our insulation and protection guide or request a coating specification.